Journal article

Molecular identification of coliform bacteria isolated from drinking water reservoirs with traditional methods and the Colilert-18 system.


Authors listKämpfer, P; Nienhüser, A; Packroff, G; Wernicke, F; Mehling, A; Nixdorf, K; Fiedler, S; Kolauch, C; Esser, M

Publication year2008

Pages374-384

JournalInternational Journal of Hygiene and Environmental Health

Volume number211

Issue number3-4

ISSN1438-4639

DOI Linkhttps://doi.org/10.1016/j.ijheh.2007.07.021

PublisherElsevier


Abstract
The accuracy of a traditional method (lactose utilization with acid and gas production) for the detection of coliform bacteria and E. coli was tested in comparison with method ISO 9308-1 (based on acid formation from lactose) and the Colilert-18 system (detection of beta-galactosidase). A total of 345 isolates were identified after isolation from water samples using API 20E strips. The Colilert-18 led to the highest number of positive findings (95% of the isolates were assigned to coliforms), whereas the ISO-9308-1 method resulted only in 29% coliform findings. With the traditional method only 15% were rated positive. Most of the isolates were identified by the API 20E system as Enterobacter spp. (species of the Enterobacter cloacae complex), Serratia spp., Citrobacter spp.and Klebsiella spp.; but species identification remained vague in several cases. A more detailed identification of 126 pure cultures by using 16S rRNA gene sequence analysis and analysis of the hsp60 gene resulted in the identification of Enterobacter nimipressuralis, E. amnigenus, E. asburiae, E. hormaechei, and Serratia fonticola as predominat coliforms. These species are beta-galactosidase positive, but show acid formation from lactose often after a prolonged incubation time. They are often not of fecal origin and may interfere with the ability to accurately detect coliforms of fecal origin.



Citation Styles

Harvard Citation styleKämpfer, P., Nienhüser, A., Packroff, G., Wernicke, F., Mehling, A., Nixdorf, K., et al. (2008) Molecular identification of coliform bacteria isolated from drinking water reservoirs with traditional methods and the Colilert-18 system., International Journal of Hygiene and Environmental Health, 211(3-4), pp. 374-384. https://doi.org/10.1016/j.ijheh.2007.07.021

APA Citation styleKämpfer, P., Nienhüser, A., Packroff, G., Wernicke, F., Mehling, A., Nixdorf, K., Fiedler, S., Kolauch, C., & Esser, M. (2008). Molecular identification of coliform bacteria isolated from drinking water reservoirs with traditional methods and the Colilert-18 system.. International Journal of Hygiene and Environmental Health. 211(3-4), 374-384. https://doi.org/10.1016/j.ijheh.2007.07.021



SDG Areas


Last updated on 2025-21-05 at 14:21