Journal article
Authors list: Amin, Amin Said; Lerche, Dietmar; Odungat, Ahammed Suhail; Boehm, Sven Uwe; Koch, Thomas; Oezcan, Fatih; Segets, Doris
Publication year: 2024
Journal: ChemCatChem
Volume number: 16
Issue number: 6
ISSN: 1867-3880
eISSN: 1867-3899
Open access status: Hybrid
DOI Link: https://doi.org/10.1002/cctc.202301393
Publisher: Wiley
Hansen Solubility Parameters (HSP), viewed in the context of similarity whenever dispersion is focused, offer valuable insights into the surface characteristics of nanoparticles. However, existing methods for determining HSP via the sedimentation of nanoparticles require multiple probe liquids, resulting in time-consuming, costly experiments with potential health risks. To address this, we developed a two-step strategy that enables a systematic selection of liquids. The key element of the approach is to first identify the rough location of the Hansen sphere in the three-dimensional Hansen space using a well-chosen set of probe liquids of different polarities and chemical structures. Then, depending on the outcome of the first step, a particular choice of liquids is made for the final HSP determination. Taken together, the introduced procedure reduces the amount of required liquids for experiments from currently more than ten to a maximum of seven chosen based on a well-defined, coherent methodology. Validation was performed on carbon black, non-pigmentary nano-scale titania, silicon/carbon composites, and lanthanum cobaltite particles, i. e., relevant materials that are commonly utilized in fuel cells, batteries, cyclohexene oxidation, catalytic combustion, photocatalysis, and heterogeneous Fenton reactions. The study showcases the potential to save time, costs, and efficiently determine HSP values in a comparable manner. Structured selection of probe liquids for Hansen parameters - Two-step-strategy: The approach is to first determine the approximate position of the 3D-Hansen sphere using a well-selected set of sample liquids of different polarity and chemical structure. Depending on the result of the first step, a specific selection of probe liquids is then made for the final HSP determination. image
Abstract:
Citation Styles
Harvard Citation style: Amin, A., Lerche, D., Odungat, A., Boehm, S., Koch, T., Oezcan, F., et al. (2024) A Procedure for Rational Probe Liquids Selection to Determine Hansen Solubility Parameters, ChemCatChem, 16(6). https://doi.org/10.1002/cctc.202301393
APA Citation style: Amin, A., Lerche, D., Odungat, A., Boehm, S., Koch, T., Oezcan, F., & Segets, D. (2024). A Procedure for Rational Probe Liquids Selection to Determine Hansen Solubility Parameters. ChemCatChem. 16(6). https://doi.org/10.1002/cctc.202301393
Keywords
Hansen Solubility Parameter; Ink Formulation; Interaction