Commissioning and performance of TITAN's Multiple-Reflection Time-of-Flight Mass-Spectrometer and isobar separator


Authors listReiter, M. P.; San Andres, S. Ayet; Bergmann, J.; Dickel, T.; Dilling, J.; Jacobs, A.; Kwiatkowski, A. A.; Plass, W. R.; Scheidenberger, C.; Short, D.; Will, C.; Babcock, C.; Dunling, E.; Finlay, A.; Hornung, C.; Jesch, C.; Klawitter, R.; Kootte, B.; Lascar, D.; Leistenschneider, E.; Murboeck, T.; Paul, S. F.; Yavor, M.

Publication year2021

JournalNuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Volume number1018

ISSN0168-9002

eISSN1872-9576

Open access statusGreen

DOI Linkhttps://doi.org/10.1016/j.nima.2021.165823

PublisherElsevier


Abstract
TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) has specialized in fast Penning Trap mass spectrometry of very short-lived radioactive isotopes. The facility has been upgraded with a Multiple-Reflection Time-of-Flight Mass Spectrometer (MR-TOF-MS) to continue its quest towards more exotic nuclides, which are critical for our understanding of nuclear structure effects far from the valley of beta stability and for the nucleosynthesis of heavy elements in explosive astrophysical environments. In this publication, we discuss the implementation, operation and performance of TITAN's MR-TOF-MS as a stand-alone high-precision mass spectrometer and as an isobar separator. By using the novel mass-selective re-trapping technique for the isobar separation, the MR-TOF-MS can consecutively perform separation and mass measurement of the same ion population, acting as its own isobar separator. The device boosts the dynamic range and reach of the TITAN facility by several orders of magnitude. The MR-TOF-MS reaches a high mass resolving power (m/Delta m similar to 400 000), high precision and mass accuracy (delta m/m < 10(-7)), is fast (common cycle time 20 ms), shows high sensitivity and very large dynamic range (ion of interest to contaminant ratios of up to 1 to 10(6)).



Citation Styles

Harvard Citation styleReiter, M., San Andres, S., Bergmann, J., Dickel, T., Dilling, J., Jacobs, A., et al. (2021) Commissioning and performance of TITAN's Multiple-Reflection Time-of-Flight Mass-Spectrometer and isobar separator, Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1018, Article 165823. https://doi.org/10.1016/j.nima.2021.165823

APA Citation styleReiter, M., San Andres, S., Bergmann, J., Dickel, T., Dilling, J., Jacobs, A., Kwiatkowski, A., Plass, W., Scheidenberger, C., Short, D., Will, C., Babcock, C., Dunling, E., Finlay, A., Hornung, C., Jesch, C., Klawitter, R., Kootte, B., Lascar, D., ...Yavor, M. (2021). Commissioning and performance of TITAN's Multiple-Reflection Time-of-Flight Mass-Spectrometer and isobar separator. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 1018, Article 165823. https://doi.org/10.1016/j.nima.2021.165823



Keywords


Exotic nucleiFACILITYHIGH-PRECISIONISACIsobar separatorMR-TOF-MSOPERATIONRadioactive Ion BeamsTITAN

Last updated on 2025-10-06 at 11:31