Journalartikel

Validation of commercial Bi2Te3-based thermoelectric generator modules for application as metrological reference samples


AutorenlisteZiolkowski, Pawel; Blaschkewitz, Przemyslaw; Mueller, Eckhard

Jahr der Veröffentlichung2021

ZeitschriftMeasurement

Bandnummer177

ISSN0263-2241

eISSN1873-412X

Open Access StatusGreen

DOI Linkhttps://doi.org/10.1016/j.measurement.2021.109247

VerlagElsevier


Abstract
Traceability and the definition of uncertainty budgets are considered as necessary prerequisites for a meaningful characterization of thermoelectric generator modules (TEM). Due to the lag of standardized measurement techniques and characterization guidelines users and developers of measurement facilities cannot express uncertainty budgets on a normative base, but can only rely on own experiences and act according to best practise approaches. Reference samples are an appropriate method to investigate the accuracy of measurements and to provide insides into strengths and weaknesses of the employed characterization methods. Such references are still not available to date for measurements on TEM. In order to overcome this deficit this article discusses the applicability of commercially available Bi2Te3-based TEM to serve as metrological reference samples. Four TEM types from different manufacturers were investigated with regard to their stability, which was assessed on the base of the internal electric resistance Ri in the course of different experiments. The modules have been tested under constant temperature differences (Delta T = 150 degrees C / 175 degrees C) but variable mechanical pressure (2 MPa < p < 3.5 MPa). Further experiments have been conducted under constant pressure (p = 3 MPa) and variable temperature differences in order to determine the short-term stability. The long-term stability was assessed from thermal cycling experiments with observation times between 117 h and 443 h in dependence of the observed module stability. Significant differences could be observed regarding the stability of Ri, which ranged from very stable module types with maximum changes of Delta Ri 2.5% to modules with a relatively weak stability showing Delta Ri 13%. The sample-to-sample variation (homogeneity) of Ri was tested in a last step on five modules from two most stable types.



Zitierstile

Harvard-ZitierstilZiolkowski, P., Blaschkewitz, P. and Mueller, E. (2021) Validation of commercial Bi2Te3-based thermoelectric generator modules for application as metrological reference samples, Measurement, 177, Article 109247. https://doi.org/10.1016/j.measurement.2021.109247

APA-ZitierstilZiolkowski, P., Blaschkewitz, P., & Mueller, E. (2021). Validation of commercial Bi2Te3-based thermoelectric generator modules for application as metrological reference samples. Measurement. 177, Article 109247. https://doi.org/10.1016/j.measurement.2021.109247



Schlagwörter


BISMUTH TELLURIDECONVERSION EFFICIENCYPARAMETER OPTIMIZATIONPressure sensitivityReference sampleROUND-ROBINSEEBECK COEFFICIENTTHERMAL INTERFACE MATERIALSThermoelectric generator moduleTRANSPORT-PROPERTIESUncertainty budgetWASTE HEAT-RECOVERY


Nachhaltigkeitsbezüge