Journalartikel

An LED/LCD-based monitoring system for the PANDA Electromagnetic Calorimeter


AutorenlisteHeld, T.; Albrecht, M.; Erlen, T.; Fink, M.; Heinsius, F. H.; Motzko, C.; Musiol, P.; Schnier, C.; Steinke, M.; Wenzel, H-C; Wiedner, U.

Jahr der Veröffentlichung2021

ZeitschriftNuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Bandnummer997

ISSN0168-9002

eISSN1872-9576

DOI Linkhttps://doi.org/10.1016/j.nima.2021.165167

VerlagElsevier


Abstract
We report on the construction of a light pulser monitoring system for the electromagnetic lead tungstate (PbWO4) calorimeter of the future (P) over bar ANDA experiment at FAIR. The system consists of a high intensity LED source, an optical fibre distribution system, and a novel and compact continuous light attenuation mechanism based on LCDs allowing operation inside the magnetic field of the (P) over bar ANDA detector. The physics objectives of the (P) over bar ANDA experiment require a highly sophisticated electromagnetic calorimeter covering an energy range spanning more than three orders of magnitude. In order to perform precision measurements with this electromagnetic calorimeter based on lead tungstate crystals in the high-luminosity environment of the (P) over bar ANDA experiment, a frequent monitoring of radiation induced transmittance losses in the crystals on a level of 0.5% is required. This precision can be achieved on a day-by-day basis between regular pi(0)/eta invariant mass calibrations, performed at least once a day.



Zitierstile

Harvard-ZitierstilHeld, T., Albrecht, M., Erlen, T., Fink, M., Heinsius, F., Motzko, C., et al. (2021) An LED/LCD-based monitoring system for the PANDA Electromagnetic Calorimeter, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 997, Article 165167. https://doi.org/10.1016/j.nima.2021.165167

APA-ZitierstilHeld, T., Albrecht, M., Erlen, T., Fink, M., Heinsius, F., Motzko, C., Musiol, P., Schnier, C., Steinke, M., Wenzel, H., & Wiedner, U. (2021). An LED/LCD-based monitoring system for the PANDA Electromagnetic Calorimeter. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 997, Article 165167. https://doi.org/10.1016/j.nima.2021.165167



Schlagwörter


ELECTROMAGNETIC CALORIMETERLead tungstateMonitoring systemScintillating crystal


Nachhaltigkeitsbezüge


Zuletzt aktualisiert 2025-02-04 um 00:30