Journalartikel

Beam test results of NDL Low Gain Avalanche Detectors (LGAD)


AutorenlisteXiao, S.; Alderweireldt, S.; Ali, S.; Allaire, C.; Agapopoulou, C.; Atanov, N.; Ayoub, M. K.; Barone, G.; Benchekroun, D.; Buzatu, A.; Caforio, D.; Castillo Garcia, L.; Chan, Y.; Chen, H.; Cindro, V; Ciucu, L.; da Costa, J. Barreiro Guimaraes; Cui, H.; Davo Miralles, F.; Davydov, Y.; d'Amen, G.; de la Taille, C.; Kiuchi, R.; Fan, Y.; Falou, A.; Ferreira, A. S. C.; Garau, M.; Ge, J.; Ghosh, A.; Giacomini, G.; Gkougkousis, E. L.; Grieco, C.; Guindon, S.; Han, D.; Han, S.; Holmberg, M.; Howard, A.; Huang, Y.; Jing, M.; Khoulaki, Y.; Kramberger, G.; Kuwertz, E.; Lefebvre, H.; Leite, M.; Leopold, A.; Li, C.; Li, Q.; Liang, H.; Liang, Z.; Liu, B.; Liu, J.; Luthfi, A.; Lyu, F.; Malyukov, S.; Mandic, I; Masetti, L.; Mikuz, M.; Nikolic, I; Polidori, L.; Polifka, R.; Posopkina, O.; Qi, B.; Ran, K.; Reynolds, B. J. G.; Rizzi, C.; Manzano, M. Robles; Rossi, E.; Rummler, A.; Sacerdoti, S.; Saito, G. T.; Seguin-Moreau, N.; Serin, L.; Shan, L.; Shi, L.; Shi, X.; Sjostrom, N. F.; Ferreira, A. Soares Canas; Soengen, J.; Stenzel, H.; Szadaj, A. J.; Tan, Y.; Terzo, S.; Thomas, J. O.; Tolley, E.; Tricoli, A.; Trincaz-Duvoid, S.; Wang, R.; Wang, S. M.; Wang, W.; Wu, K.; Yang, T.; Yang, Y.; Yu, C.; Zhang, X.; Zhao, L.; Zhao, M.; Zhao, Z.; Zheng, X.; Zhuang, X.

Jahr der Veröffentlichung2021

ZeitschriftNuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Bandnummer989

ISSN0168-9002

eISSN1872-9576

Open Access StatusGreen

DOI Linkhttps://doi.org/10.1016/j.nima.2020.164956

VerlagElsevier


Abstract
A High-Granularity Timing Detector (HGTD) is proposed based on the Low-Gain Avalanche Detector (LGAD) for the ATLAS experiment to satisfy the time resolution requirement for the up-coming High Luminosity at LHC (HL-LHC). We report on beam test results for two proto-types LGADs (BV60 and BV170) developed for the HGTD. Such modules were manufactured by the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences (CAS) collaborated with Novel Device Laboratory (NDL) of the Beijing Normal University. The beam tests were performed with 5 GeV electron beam at DESY. The timing performance of the LGADs was compared to a trigger counter consisting of a quartz bar coupled to a SiPM readout while extracting reference SiPM by fitting with a Gaussian function. The time resolution was obtained as 41 ps and 63 ps for the BV60 and the BV170, respectively.



Zitierstile

Harvard-ZitierstilXiao, S., Alderweireldt, S., Ali, S., Allaire, C., Agapopoulou, C., Atanov, N., et al. (2021) Beam test results of NDL Low Gain Avalanche Detectors (LGAD), Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 989, Article 164956. https://doi.org/10.1016/j.nima.2020.164956

APA-ZitierstilXiao, S., Alderweireldt, S., Ali, S., Allaire, C., Agapopoulou, C., Atanov, N., Ayoub, M., Barone, G., Benchekroun, D., Buzatu, A., Caforio, D., Castillo Garcia, L., Chan, Y., Chen, H., Cindro, V., Ciucu, L., da Costa, J., Cui, H., Davo Miralles, F., ...Zhuang, X. (2021). Beam test results of NDL Low Gain Avalanche Detectors (LGAD). Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 989, Article 164956. https://doi.org/10.1016/j.nima.2020.164956



Schlagwörter


CFDElectron beamLGADTime resolution

Zuletzt aktualisiert 2025-10-06 um 11:21