Journal article

Commissioning and performance of the Belle II pixel detector


Authors listYe, H.; Abudinen, F.; Ackermann, K.; Ahlburg, P.; Albalawi, M.; Alonso, O.; Andricek, L.; Ayad, R.; Babu, V.; Bilka, T.; Boronat, M.; Bozek, A.; Camien, C.; Caldwell, A.; Chekelian, V.; Deschamps, B.; Dieguez, A.; Dingfelder, J.; Dolezal, Z.; Esperante, D.; Fras, M.; Frey, A.; Fuster, J.; Gabriel, M.; Gadow, K.; Gebauer, U.; Gessler, T.; Giakoustidis, G.; Gioi, L.; Gomis, P.; Greenwald, D.; Heck, M.; Hemperek, T.; Hensel, M.; Hoek, M.; Huber, S.; Kandra, J.; Kapusta, P.; Kiesling, C.; Kisielewski, B.; Kittlinger, D.; Klose, D.; Kodys, P.; Koffmane, C.; Konorov, I.; Krivokuca, S.; Krueger, H.; Kuhr, T.; Kvasnicka, P.; Lacasta, C.; Lange, J. S.; Lautenbach, K.; Leis, U.; Leitl, P.; Levit, D.; Liemann, G.; Liu, Q.; Liu, Z.; Lueck, T.; Luetticke, F.; Macharski, L.; Marinas, C.; Mccarney, S.; Moser, H. G.; Moya, D.; Mueller, F. J.; Mueller, F.; Niebuhr, C.; Ninkovic, J.; Paschen, B.; Paul, S.; Peric, I.; Poblotzki, F.; Rabusov, A.; Reiter, S. P.; Richter, R.; Ritter, M.; Ritzert, M.; Sanchez, J. G.; Scavino, B.; Schaller, G.; Schnecke, M.; Schopper, F.; Schreeck, H.; Schwenker, B.; Sedlmeyer, R.; Sfienti, C.; Simon, F.; Skambraks, S.; Soloviev, Y.; Spruck, B.; Stefkova, S.; Stever, R.; Stolzenberg, U.; Tafelmayer, E.; Takahashi, M.; Vila, I.; Virto, A. L.; Vogt, S.; Vos, M.; Wang, C.; Wermes, N.; Wessel, C.; Wieduwilt, P.; Windel, H.; Zhao, J.

Publication year2021

JournalNuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Volume number987

ISSN0168-9002

eISSN1872-9576

DOI Linkhttps://doi.org/10.1016/j.nima.2020.164875

PublisherElsevier


Abstract
The Belle II experiment at the SuperKEKB energy-asymmetric e(+)e(-) collider has completed a series of substantial upgrades and started collecting data in 2019. The experiment is expected to accumulate a data set of 50 ab(-1) to explore new physics beyond the Standard Model at the intensity frontier. The pixel detector (PXD) of Belle II plays a key role in vertex determination. It has been developed using the DEpleted P-channel Field Effect Transistor (DEPFET) technology, which combines low power consumption in the active pixel area and low intrinsic noise with a very small material budget. In this paper, commissioning and performance of the PXD measured with first collision data are presented.



Citation Styles

Harvard Citation styleYe, H., Abudinen, F., Ackermann, K., Ahlburg, P., Albalawi, M., Alonso, O., et al. (2021) Commissioning and performance of the Belle II pixel detector, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 987, Article 164875. https://doi.org/10.1016/j.nima.2020.164875

APA Citation styleYe, H., Abudinen, F., Ackermann, K., Ahlburg, P., Albalawi, M., Alonso, O., Andricek, L., Ayad, R., Babu, V., Bilka, T., Boronat, M., Bozek, A., Camien, C., Caldwell, A., Chekelian, V., Deschamps, B., Dieguez, A., Dingfelder, J., Dolezal, Z., ...Zhao, J. (2021). Commissioning and performance of the Belle II pixel detector. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 987, Article 164875. https://doi.org/10.1016/j.nima.2020.164875



Keywords


Belle IIDEPFETPixel detector

Last updated on 2025-02-04 at 00:34