Journalartikel

New Intraoral Scanner-Based Chairside Measurement Method to Investigate the Internal Fit of Crowns: A Clinical Trial


AutorenlisteSchlenz, Maximiliane Amelie; Vogler, Jonas; Schmidt, Alexander; Rehmann, Peter; Woestmann, Bernd

Jahr der Veröffentlichung2020

ZeitschriftInternational Journal of Environmental Research and Public Health

Bandnummer17

Heftnummer7

eISSN1660-4601

Open Access StatusGold

DOI Linkhttps://doi.org/10.3390/ijerph17072182

VerlagMDPI


Abstract
To measure the internal fit of the computer-aided designed/computer-aided manufactured (CAD/CAM) crowns, a new scanner-based chairside approach was investigated in patients, and the results were compared to the established silicone replica technique and a digital laboratory replica method. Thirty full-coverage crown preparations were included. Based on a digital impression with an intraoral scanner (IOS, Trios 3), three CAD/CAM measurement copings ('COM', resin composite; 'ZIR', zirconium dioxide; 'NPA', non-precious alloy) were fabricated for each tooth preparation. The internal fit of the measurement copings was analyzed with three different evaluation methods: IOS-based digital approach (D-IOS), digital replica method with laboratory software (D-GOM), and conventional silicone replica technique (CV-SR). The congruence between the determined target parameter of the 80-mu m cement space and the actual measured internal gap was investigated. Statistical analysis was performed by ANOVA (p-value < 0.05). No significant difference was determined between the three evaluation methods. However, significant differences were observed for the three coping materials (p-value < 0.05), the single measurement position (marginal, axial, and occlusal fit) (p-value < 0.05), and the interaction between the coping material and the measurement position (p-value < 0.05). COM revealed the smallest internal gap, followed by ZIR and NPA. Regardless of the coping material, the occlusal gap was higher than the axial and marginal gaps. Furthermore, only the internal gaps of the marginal area almost matched the target parameter of 80-mu m for the cement space. D-IOS is effective for measuring internal fit of single crowns in different clinical settings.



Zitierstile

Harvard-ZitierstilSchlenz, M., Vogler, J., Schmidt, A., Rehmann, P. and Woestmann, B. (2020) New Intraoral Scanner-Based Chairside Measurement Method to Investigate the Internal Fit of Crowns: A Clinical Trial, International Journal of Environmental Research and Public Health, 17(7), Article 2182. https://doi.org/10.3390/ijerph17072182

APA-ZitierstilSchlenz, M., Vogler, J., Schmidt, A., Rehmann, P., & Woestmann, B. (2020). New Intraoral Scanner-Based Chairside Measurement Method to Investigate the Internal Fit of Crowns: A Clinical Trial. International Journal of Environmental Research and Public Health. 17(7), Article 2182. https://doi.org/10.3390/ijerph17072182



Schlagwörter


4-UNIT FDPSCAD-CAMCAD/CAM SYSTEMSChairsidedental crownsDIGITAL EVALUATIONIMPRESSIONSINTERNAL FITIntraoral ScannerMARGINAL FITReplica techniqueRESTORATIONSTHICKNESS


Nachhaltigkeitsbezüge


Zuletzt aktualisiert 2025-10-06 um 11:11