Journal article

Chairside measurement of the marginal and internal fit of crowns: a new intraoral scan-based approach


Authors listSchlenz, Maximiliane Amelie; Vogler, Jonas Adrian Helmut; Schmidt, Alexander; Rehmann, Peter; Woestmann, Bernd

Publication year2020

Pages2459-2468

JournalClinical Oral Investigations

Volume number24

Issue number7

ISSN1432-6981

eISSN1436-3771

DOI Linkhttps://doi.org/10.1007/s00784-019-03108-3

PublisherSpringer


Abstract
Objectives To investigate the marginal and internal fit of crowns, a new intraoral scanner-based digital approach for chairside measurement (D-IOS) was systematically analysed and compared with the conventional silicone replica technique (CV-SR) and digital 3D analysis software (D-GOM). Materials and methods Two models, representing different clinical situations, were constructed, and the first molar was prepared for a full-coverage crown. On the basis of an intraoral scan (Trios 3), copings of three different materials (non-precious alloy, zirconium dioxide, and resin composite) with two different cement spaces (80 mu m, 50 mu m) were manufactured. The fit of the copings was investigated by all three methods (CV-SR, D-IOS, D-GOM). Therefore, the cement space was visualized with low-viscosity silicone and digitalized with a second intraoral scan. Evaluation of fit by the D-IOS-method was measured in the intraoral scanner software, whereas for analysis by D-GOM, both intraoral scan datasets were transferred to 3D analysis software (GOM Inspect). The CV-SR-method was used as a control group. For all copings, the measurements were repeated five times. The data were analysed with ANOVA. Results No significant differences between the three evaluation methods and the coping materials were shown. However, in the occlusal area, the internal gap was significantly higher compared to the internal gap in the marginal and axial areas regardless of the cement space setting (p < .05). The target parameter of the cement spaces did not match the actual measured internal gaps. Conclusions All three evaluation methods and coping materials can be used for the measurement of fit within different clinical situations.



Citation Styles

Harvard Citation styleSchlenz, M., Vogler, J., Schmidt, A., Rehmann, P. and Woestmann, B. (2020) Chairside measurement of the marginal and internal fit of crowns: a new intraoral scan-based approach, Clinical Oral Investigations, 24(7), pp. 2459-2468. https://doi.org/10.1007/s00784-019-03108-3

APA Citation styleSchlenz, M., Vogler, J., Schmidt, A., Rehmann, P., & Woestmann, B. (2020). Chairside measurement of the marginal and internal fit of crowns: a new intraoral scan-based approach. Clinical Oral Investigations. 24(7), 2459-2468. https://doi.org/10.1007/s00784-019-03108-3



Keywords


4-UNIT FDPSALLOYCAMChairsideCOCRCOPINGSDIGITAL EVALUATIONINTERNAL FITIntraoral ScannerMARGINAL FITReplica techniqueRESTORATIONS

Last updated on 2025-21-05 at 18:24