PURPOSE OF THE STUDY

With the concept of the lateral compression plate (LLCP) a technique has been available designed to combine the advantages of a fixed-angle fixation with a complete sinking of the implant into the proximal bone. The objective of the present study was to investigate the results of the LLCP compared with classical screw osteosynthesis (SO).

MATERIAL AND METHODS

31 patients with pes planovalgus who received calcaneal displacement osteotomy and osteosyntheses with screws (n = 17) or LLCP (n = 14) between 2010 and 2015 were investigated retrospectively.The ankle-hindfoot scale, Kaikkonen score, VAS, and the SF-36 were determined preoperatively as well as at the last clinical follow-up. In addition, a radiological control of osseous integration was performed in all patients 12 weeks after surgery.

RESULTS

With regard to clinical scores both methods depicted significant improvement. In the overall cohort there were no pseudarthroses. In the SO group 5 cases (29%) showed hardware irritation, in the LLCP group there were none. Results in the LLCP group were significantly superior in the area of the physical section of the SF 36.

CONCLUSIONS

Based on the results of our study, surgical treatment of stage II pes planovalgus by means of calcaneal displacement osteotomy using the LLCP is equivalent to SO with a lower incidence of hardware irritation.




Citation Styles

Harvard Citation styleMueller, C., Zippelius, T., Strube, P., Seeger, J., Brinkmann, O., Matziolis, G., et al. (2018) Calcaneal Displacement Osteotomies - Less Soft Tissue Irritation in Lateral Compression Plate than Screws, Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca, 85(1), pp. 54-56

APA Citation styleMueller, C., Zippelius, T., Strube, P., Seeger, J., Brinkmann, O., Matziolis, G., & Wagner, A. (2018). Calcaneal Displacement Osteotomies - Less Soft Tissue Irritation in Lateral Compression Plate than Screws. Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca. 85(1), 54-56.



Keywords


ADULT ACQUIRED FLATFOOThardware irritationlateral compression plateosteosynthesispes planovalgusPOSTERIORscrewTIBIAL TENDON RECONSTRUCTION


SDG Areas


Last updated on 2025-02-04 at 01:23