AutorenlisteDuncker, David; Westenfeld, Ralf; Konrad, Torsten; Pfeffer, Tobias; de Freitas, Carlos A. Correia; Pfister, Roman; Thomas, Dierk; Fuernkranz, Alexander; Andrie, Rene P.; Napp, Andreas; Schmitt, Joern; Karolyi, Laszlo; Wakili, Reza; Hilfiker-Kleiner, Denise; Bauersachs, Johann; Veltmann, Christian

Jahr der Veröffentlichung2017

Seiten582-589

ZeitschriftClinical Research in Cardiology

Bandnummer106

Heftnummer8

ISSN1861-0684

eISSN1861-0692

Open Access StatusHybrid

DOI Linkhttps://doi.org/10.1007/s00392-017-1090-5

VerlagSpringer


Abstract

Introduction Peripartum cardiomyopathy (PPCM) is a rare cardiomyopathy characterized by an acute reduction in left ventricular ejection fraction (LVEF). Sudden deaths during the course of PPCM are reported to be elevated, the underlying mechanisms remains unknown. The aim of the present multi-centre study was to evaluate the arrhythmia burden in a multi-centre approach in patients with PPCM using a wearable cardioverter/defibrillator (WCD).

Methods and results Forty-nine patients from 16 German centres with newly diagnosed PPCM and LVEF <= 35% receiving a WCD were included in this retrospective analysis. Mean follow-up was 15 +/- 10 months. At diagnosis, mean age was 33 +/- 5 years, parity was 2.1 +/- 1.6, LVEF was 21 +/- 7%, NYHA functional class was 3.4 +/- 0.7. Mean wear time was 120 +/- 106 days, mean wear time per day was 21.4 +/- 3.3 h. Six (12%) patients presented eight ventricular tachyarrhythmias during WCD period: five episodes of VF, two sustained ventricular tachycardia (VT) and one non-sustained VT occurred.

Conclusion This multicentre study underpins the elevated risk for ventricular tachyarrhythmias in patients with newly diagnosed PPCM and reduced LVEF. A WCD should be considered for 3-6 months in these patients to prevent sudden cardiac death from ventricular tachyarrhythmias.




Zitierstile

Harvard-ZitierstilDuncker, D., Westenfeld, R., Konrad, T., Pfeffer, T., de Freitas, C., Pfister, R., et al. (2017) Risk for life-threatening arrhythmia in newly diagnosed peripartum cardiomyopathy with low ejection fraction: a German multi-centre analysis, Clinical Research in Cardiology, 106(8), pp. 582-589. https://doi.org/10.1007/s00392-017-1090-5

APA-ZitierstilDuncker, D., Westenfeld, R., Konrad, T., Pfeffer, T., de Freitas, C., Pfister, R., Thomas, D., Fuernkranz, A., Andrie, R., Napp, A., Schmitt, J., Karolyi, L., Wakili, R., Hilfiker-Kleiner, D., Bauersachs, J., & Veltmann, C. (2017). Risk for life-threatening arrhythmia in newly diagnosed peripartum cardiomyopathy with low ejection fraction: a German multi-centre analysis. Clinical Research in Cardiology. 106(8), 582-589. https://doi.org/10.1007/s00392-017-1090-5



Schlagwörter


CARDIOLOGY WORKING GROUPEUROPEAN-SOCIETYHEART-FAILURE ASSOCIATIONLEFT-VENTRICULAR FUNCTIONPERIPARTUM CARDIOMYOPATHYREGISTRYSudden cardiac deathVentricular tachyarrhythmiaWearable cardioverter/defibrillatorWEARABLE CARDIOVERTER-DEFIBRILLATORWOMEN

Zuletzt aktualisiert 2025-10-06 um 10:46