Conference paper

Precise determination of the 1s Lamb Shift in hydrogen-like heavy ions at the ESR storage ring using microcalorimeters


Authors listKraft-Bermuth, S.; Andrianov, V.; Bleile, A.; Echler, A.; Egelhof, P.; Grabitz, P.; Ilieva, S.; Kiselev, O.; Kilbourne, C.; McCammon, D.; Meier, J. P.; Scholz, P.

Publication year2015

JournalPhysica Scripta

Volume numberT166

ISSN0031-8949

eISSN1402-4896

DOI Linkhttps://doi.org/10.1088/0031-8949/2015/T166/014028

Conference9th International Conference on Nuclear Physics at Storage Rings (STORI)

PublisherIOP Publishing


Abstract
The precise determination of the energy of the Lyman alpha 1 and alpha 2 lines in hydrogen-like heavy ions provides a sensitive test of quantum electrodynamics in very strong Coulomb fields. To improve the precision of such experiments, the new detector concept of microcalorimeters, which detect the temperature change of an absorber after an incoming particle or photon has deposited its energy as heat, is now exploited. The microcalorimeters for x-rays used in these experiments consist of arrays of silicon thermometers and x-ray absorbers made of high-Z material. With such detectors, a relative energy resolution of about 1 per mille is obtained in the energy regime of 50-100 keV. Two successful measurement campaigns to determine the 1s Lamb Shift in Pb81+ and Au78+ have been completed: a prototype array has been applied successfully for the determination of the 1s Lamb Shift of Pb81+ at the ESR storage ring at GSI in a first test experiment. Based on the results of this test, a full array with 32 pixels has been equipped and has recently been applied to determine the 1s Lamb Shift in Au78+ ions. The energy of the Lyman-alpha 1 line agrees within error bars well with theoretical predictions. The obtained accuracy is already comparable to the best accuracy obtained with conventional germanium detectors for hydrogen-like uranium.



Citation Styles

Harvard Citation styleKraft-Bermuth, S., Andrianov, V., Bleile, A., Echler, A., Egelhof, P., Grabitz, P., et al. (2015) Precise determination of the 1s Lamb Shift in hydrogen-like heavy ions at the ESR storage ring using microcalorimeters, Physica Scripta, T166, Article 014028. https://doi.org/10.1088/0031-8949/2015/T166/014028

APA Citation styleKraft-Bermuth, S., Andrianov, V., Bleile, A., Echler, A., Egelhof, P., Grabitz, P., Ilieva, S., Kiselev, O., Kilbourne, C., McCammon, D., Meier, J., & Scholz, P. (2015). Precise determination of the 1s Lamb Shift in hydrogen-like heavy ions at the ESR storage ring using microcalorimeters. Physica Scripta. T166, Article 014028. https://doi.org/10.1088/0031-8949/2015/T166/014028



Keywords


high-precision X-ray spectroscopyLOW-TEMPERATURE DETECTORSmicrocalorimeters for x-raystests of QEDX-RAY SPECTROSCOPY