Journal article
Authors list: Lalovic, N.; Louchart, C.; Michelagnoli, C.; Perez-Vidal, R. M.; Ralet, D.; Gerl, J.; Rudolph, D.; Arici, T.; Bazzacco, D.; Clement, E.; Gadea, A.; Kojouharov, I.; Korichi, A.; Labiche, M.; Ljungvall, J.; Lopez-Martens, A.; Nyberg, J.; Pietralla, N.; Pietri, S.; Stezowski, O.
Publication year: 2016
Pages: 258-266
Journal: Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume number: 806
ISSN: 0168-9002
eISSN: 1872-9576
Open access status: Green
DOI Link: https://doi.org/10.1016/j.nima.2015.10.032
Publisher: Elsevier
Abstract:
In contemporary nuclear physics, the European Advanced GAmma Tracking Array (AGATA) represents a crucial detection system for cutting-edge nuclear structure studies. AGATA consists of highly segmented high-purity germanium crystals and uses the pulse-shape analysis technique to determine both the position and the energy of the y-ray interaction points in the crystals. It is the tracking algorithms that deploy this information and enable insight into the sequence of interactions, providing information on the full or partial absorption of the 7 ray. A series of dedicated performance measurements for an AGATA set-up comprising 21 crystals is described. This set-up was used within the recent PreSPEC-AGATA experimental campaign at the GSI Helmholtzzentrum fur Schwerionenforschung. Using the radioactive sources Co-56, Co-60 and Eu-152, absolute and normalized efficiencies and the peak-to-total of the array were measured. These quantities are discussed using different data analysis procedures. The quality of the pulse-shape analysis and the tracking algorithm are evaluated. The agreement between the experimental data and the Geant4 simulations is also investigated. (C) 2015 Elsevier B.V. All rights
Citation Styles
Harvard Citation style: Lalovic, N., Louchart, C., Michelagnoli, C., Perez-Vidal, R., Ralet, D., Gerl, J., et al. (2016) Performance of the AGATA γ-ray spectrometer in the PreSPEC set-up at GSI, Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 806, pp. 258-266. https://doi.org/10.1016/j.nima.2015.10.032
APA Citation style: Lalovic, N., Louchart, C., Michelagnoli, C., Perez-Vidal, R., Ralet, D., Gerl, J., Rudolph, D., Arici, T., Bazzacco, D., Clement, E., Gadea, A., Kojouharov, I., Korichi, A., Labiche, M., Ljungvall, J., Lopez-Martens, A., Nyberg, J., Pietralla, N., Pietri, S., ...Stezowski, O. (2016). Performance of the AGATA γ-ray spectrometer in the PreSPEC set-up at GSI. Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 806, 258-266. https://doi.org/10.1016/j.nima.2015.10.032
Keywords
ARRAYS; CONCEPTUAL DESIGN; Gamma-ray spectroscopy; Gamma-ray tracking; GERMANIUM; HPGe detectors; nuclear structure; Pulse shape analysis