Journalartikel

Influences of fit and fill following hip arthroplasty using a cementless short-stem prosthesis


AutorenlisteJahnke, Alexander; Engl, Sandra; Seeger, Joern Bengt; Basad, Erhan; Rickert, Markus; Ishaque, Bernd Alexander

Jahr der Veröffentlichung2015

Seiten1609-1614

ZeitschriftArchives of Orthopaedic and Trauma Surgery

Bandnummer135

Heftnummer11

ISSN0936-8051

eISSN1434-3916

DOI Linkhttps://doi.org/10.1007/s00402-015-2302-y

VerlagSpringer


Abstract

The purpose of this study consisted in examining the effects of fit and fill ratio of the Metha (A (R)) prosthesis (BBraun, Aesculap, Tuttlingen, Germany) on radiological and clinical outcomes at a follow-up of 1 year.

40 patients were included. Fit and fill ratio measurements, radiological and clinical examinations were performed preoperatively and postoperatively. Correlations were established between fit and fill ratio, and potential factors like sex, age, body mass index, Harris Hip Score and changes of radiological signs.

The whole cohort (100 %) had a tight fit and fill ratio (> 0.8) at the proximal level and at each follow-up. "Champagne-flute" configuration provoked high distal tight-fit and fill ratio. Poor distal fit and fill ratio compared to the proximal and the mid-stem level was measurable at each follow-up (p < 0.05). Correlations between fit and fill ratio and preoperative femur configurations were detectable.

Implanting the Metha(A (R)) prosthesis induces tight fit and fill ratio at the proximal and coated sections. Preoperative femur configuration should be considered to achieve best fit and fill situation and therefore excellent primary stability. In most cases "normal" and "stove-pipe" configurations provide good proximal fit and fill. Since "champagne-flute" configuration induces undesirable tight distal fit and fill ratio the size of the Metha (A (R)) stem should be adequately increased to achieve a more proximal load transmission.




Zitierstile

Harvard-ZitierstilJahnke, A., Engl, S., Seeger, J., Basad, E., Rickert, M. and Ishaque, B. (2015) Influences of fit and fill following hip arthroplasty using a cementless short-stem prosthesis, Archives of Orthopaedic and Trauma Surgery, 135(11), pp. 1609-1614. https://doi.org/10.1007/s00402-015-2302-y

APA-ZitierstilJahnke, A., Engl, S., Seeger, J., Basad, E., Rickert, M., & Ishaque, B. (2015). Influences of fit and fill following hip arthroplasty using a cementless short-stem prosthesis. Archives of Orthopaedic and Trauma Surgery. 135(11), 1609-1614. https://doi.org/10.1007/s00402-015-2302-y



Schlagwörter


DESIGNSFEMORAL COMPONENTSFit and fillFRACTURESPreoperative femur configurationREPLACEMENTShort stemSURVIVORSHIPTHA


Nachhaltigkeitsbezüge


Zuletzt aktualisiert 2025-21-05 um 18:34