Journal article

Changes of periprosthetic bone density after a cementless short hip stem: a clinical and radiological analysis


Authors listJahnke, Alexander; Engl, Sandra; Altmeyer, Corinna; Jakubowitz, Eike; Seeger, Joern Bengt; Rickert, Markus; Ishaque, Bernd Alexander

Publication year2014

Pages2045-2050

JournalInternational Orthopaedics

Volume number38

Issue number10

ISSN0341-2695

eISSN1432-5195

DOI Linkhttps://doi.org/10.1007/s00264-014-2370-6

PublisherSpringer


Abstract

The purpose of this study was to examine the concept of proximal load initiation of a total short-stemmed hip arthroplasty (MethaA (R) BBraun, Aesculap, Tuttlingen, Germany) on the basis of bone variations by means of osteodensitometric dual energy X-ray absorptiometry and radiologic measurements.

After power analysis 40 patients were included in this study. DXA examination, radiological and clinical follow-up was performed pre-operatively and postoperatively. Socio-demographic relevancies of bone progression and radiological changes were raised epidemiologically and clinically.

Improvement of the Harris hip score from 54.7 points preoperative to 96.7 points postoperative was detected (p < 0.01). Loss of summarized overall net average bone mass density (netavg BMD) could only be manifested after six months compared to the netavg BMD of the postoperative measurement (p < 0.01). After six and 12 months BMD atrophy was shown mainly in regions of interest (ROI) 1, 4 and 7. Positive correlations between changes of BMD and age, male sex and BMI were detectable. No stem had to be revised.

The MethaA (R) implant shows excellent osseointegration at the coated area of the stem without factors of aseptic loosening in the short term. This study shows that parameters like age, sex and BMI influence BMD progression and stress shielding. MethaA (R) implant shows excellent results especially in young patients with good bone stock.




Citation Styles

Harvard Citation styleJahnke, A., Engl, S., Altmeyer, C., Jakubowitz, E., Seeger, J., Rickert, M., et al. (2014) Changes of periprosthetic bone density after a cementless short hip stem: a clinical and radiological analysis, International Orthopaedics, 38(10), pp. 2045-2050. https://doi.org/10.1007/s00264-014-2370-6

APA Citation styleJahnke, A., Engl, S., Altmeyer, C., Jakubowitz, E., Seeger, J., Rickert, M., & Ishaque, B. (2014). Changes of periprosthetic bone density after a cementless short hip stem: a clinical and radiological analysis. International Orthopaedics. 38(10), 2045-2050. https://doi.org/10.1007/s00264-014-2370-6



Keywords


ARTHROPLASTYbone densityDensitometryDXAESKAFEMORAL COMPONENTSREPLACEMENTREPRODUCIBILITYShort stemTHAX-RAY ABSORPTIOMETRY

Last updated on 2025-21-05 at 18:36