Journal article

Tests of optical glues for the PANDA electromagnetic calorimeter


Authors listDbeyssi, A.; Tomasi-Gustafsson, E.; Hennino, T.; Imre, M.; Kunne, R.; Le Galliard, C.; Marchand, D.; Maroni, A.; Ramstein, B.; Rosier, P.; Bremer, D.; Dormenev, V.; Eissner, T.; Kuske, T.; Novotny, R.; Moeini, H.; Bondarenko, O.; Kavatsyuk, M.; Loehner, H.; Messchendorp, G.; Tambave, G.

Publication year2013

Pages82-86

JournalNuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Volume number722

ISSN0168-9002

DOI Linkhttps://doi.org/10.1016/j.nima.2013.04.057

PublisherElsevier


Abstract
This paper reports on the results of tests for low temperature applications of two commercial optical glues in the electromagnetic calorimeter of PANDA at FAIR. Mechanical, thermal and optical properties are presented, as well as radiation hardness to photon and proton radiation. (C) 2013 Elsevier B.V. All rights reserved.



Citation Styles

Harvard Citation styleDbeyssi, A., Tomasi-Gustafsson, E., Hennino, T., Imre, M., Kunne, R., Le Galliard, C., et al. (2013) Tests of optical glues for the PANDA electromagnetic calorimeter, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 722, pp. 82-86. https://doi.org/10.1016/j.nima.2013.04.057

APA Citation styleDbeyssi, A., Tomasi-Gustafsson, E., Hennino, T., Imre, M., Kunne, R., Le Galliard, C., Marchand, D., Maroni, A., Ramstein, B., Rosier, P., Bremer, D., Dormenev, V., Eissner, T., Kuske, T., Novotny, R., Moeini, H., Bondarenko, O., Kavatsyuk, M., Loehner, H., ...Tambave, G. (2013). Tests of optical glues for the PANDA electromagnetic calorimeter. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 722, 82-86. https://doi.org/10.1016/j.nima.2013.04.057



Keywords


ELECTROMAGNETIC CALORIMETERIrradiation testsOptical glues

Last updated on 2025-02-04 at 02:26