Journal article

Comparison of Central Retinal Thickness in Healthy Children and Adults Measured with the Heidelberg Spectralis OCT and the Zeiss Stratus OCT 3


Authors listChopovska, Yaroslava; Jaeger, Melanie; Rambow, Ronny; Lorenz, Birgit

Publication year2011

Pages27-36

JournalOphthalmologica: The European Retina Journal

Volume number225

Issue number1

ISSN0030-3755

eISSN1423-0267

DOI Linkhttps://doi.org/10.1159/000316693

PublisherKarger Publishers


Abstract
Background/Aims: To compare retinal thickness measurements obtained by the Spectralis and Stratus OCT 3 in healthy children and adults. Methods: Central volume scan (25-scan pattern) and macular thickness map protocols were performed subsequently using the Spectralis OCT and Stratus OCT 3 on a randomly selected eye of 34 healthy adults (18-50 years) and 20 children (6-17 years). Nine Early Treatment Diabetic Retinopathy Study (ETDRS) subfields were analyzed and compared between the children and adults. Results: All retinal thickness measurements obtained by the Spectralis OCT were greater than those measured with the Stratus OCT 3 (p < 0.01). In adults, the mean paired difference of measurements with both devices was 64.9 +/- 13.2 mu m (central minimum) and 75.8 +/- 4.7 mu m (central subfield). In children, the respective values were 56.6 +/- 13.1 mu m and 69.7 +/- 9.1 mu m, being significantly lower (p < 0.05). Conclusion: In healthy eyes, measurements with the Stratus OCT 3 can be adjusted to measurements obtained using the Spectralis OCT by the values mentioned above, considering differences between children and adults. Copyright (C) 2010 S. Karger AG, Basel



Citation Styles

Harvard Citation styleChopovska, Y., Jaeger, M., Rambow, R. and Lorenz, B. (2011) Comparison of Central Retinal Thickness in Healthy Children and Adults Measured with the Heidelberg Spectralis OCT and the Zeiss Stratus OCT 3, Ophthalmologica: The European Retina Journal, 225(1), pp. 27-36. https://doi.org/10.1159/000316693

APA Citation styleChopovska, Y., Jaeger, M., Rambow, R., & Lorenz, B. (2011). Comparison of Central Retinal Thickness in Healthy Children and Adults Measured with the Heidelberg Spectralis OCT and the Zeiss Stratus OCT 3. Ophthalmologica: The European Retina Journal. 225(1), 27-36. https://doi.org/10.1159/000316693



Keywords


Age dependenceAXIAL LENGTHMACULAR THICKNESSNORMATIVE DATAOPTICAL COHERENCE TOMOGRAPHYOptical coherence tomography, spectral domainREPRODUCIBILITYRetinal thicknessTime domain

Last updated on 2025-02-04 at 02:59