Journal article

Arthroscopic fixation of posterior cruciate ligament avulsion fractures: a new minimally invasive technique


Authors listHoras, Uwe; Meissner, Stefan A.; Heiss, Christian; Schnettler, Reinhard

Publication year2010

Pages781-783

JournalKnee Surgery, Sports Traumatology, Arthroscopy

Volume number18

Issue number6

ISSN0942-2056

DOI Linkhttps://doi.org/10.1007/s00167-009-0937-3

PublisherWiley


Abstract
We present a new all-inside technique for the reduction and fixation of posterior cruciate ligament avulsion fractures. Two suture discs and a mersilene band are used to continuously exert even pressure on the avulsion fragment, thereby maintaining reduction during healing. The risk of a loss of reduction and further fragmentation is minimized.



Citation Styles

Harvard Citation styleHoras, U., Meissner, S., Heiss, C. and Schnettler, R. (2010) Arthroscopic fixation of posterior cruciate ligament avulsion fractures: a new minimally invasive technique, Knee Surgery, Sports Traumatology, Arthroscopy, 18(6), pp. 781-783. https://doi.org/10.1007/s00167-009-0937-3

APA Citation styleHoras, U., Meissner, S., Heiss, C., & Schnettler, R. (2010). Arthroscopic fixation of posterior cruciate ligament avulsion fractures: a new minimally invasive technique. Knee Surgery, Sports Traumatology, Arthroscopy. 18(6), 781-783. https://doi.org/10.1007/s00167-009-0937-3