Journal article

Experimental research of high frequency tapered pulse tube cooler


Authors listYang, L. W.

Publication year2009

Pages738-741

JournalCryogenics

Volume number49

Issue number12

ISSN0011-2275

eISSN1879-2235

DOI Linkhttps://doi.org/10.1016/j.cryogenics.2009.09.002

PublisherElsevier


Abstract
Tapered pulse tube, corresponding to traditional cylinder tube, is a special design of pulse tube coolers. In this paper, different types of tapered pulse tube arrangements with different angles are tested based on our optimized high frequency PTC. Experiments show that PTCs with tapered PTCs, either to hot or cold end, degrade the performance of PTC in comparison to the cylinder tube. This paper proposes and tests for the first time CD tapered pulse tube. This special tapered pulse tube from two directions, with big diameter at two ends and small diameter in the middle, is similar to converging-diverging nozzle. It improves the performance of PTC over the optimized cylinder tube, though the improvement is only about 1-2 K in minimum temperature. (C) 2009 Elsevier Ltd. All rights reserved.



Citation Styles

Harvard Citation styleYang, L. (2009) Experimental research of high frequency tapered pulse tube cooler, Cryogenics, 49(12), pp. 738-741. https://doi.org/10.1016/j.cryogenics.2009.09.002

APA Citation styleYang, L. (2009). Experimental research of high frequency tapered pulse tube cooler. Cryogenics. 49(12), 738-741. https://doi.org/10.1016/j.cryogenics.2009.09.002



Keywords


2-DIMENSIONAL MODELCD tapered pulse tubeHigh frequency pulse tube cooler (E)REFRIGERATORSTaper tube

Last updated on 2025-02-04 at 03:09