Conference paper

Isobar separation by time-of-flight mass spectrometry for low-energy radioactive ion beam facilities


Authors listPlass, Wolfgang R.; Dickel, Timo; Czok, Ulrich; Geissel, Hans; Petrick, Martin; Reinheimer, Katrin; Scheidenberger, Christoph; Yavor, Mikhail I.

Publication year2008

Pages4560-4564

JournalNuclear Instruments and Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms

Volume number266

Issue number19-20

ISSN0168-583X

eISSN1872-9584

DOI Linkhttps://doi.org/10.1016/j.nimb.2008.05.079

Conference15th International Conference on Electromagnetic Isotope Separators and Techniques Related to their Applications

PublisherElsevier


Abstract
A multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) system for low-energy radioactive ion beam facilities has been developed, which can be used for (i) isobar separation and (ii) direct mass measurements of very short-lived nuclei with half-lives of about 1 ms or longer, and (iii) for identification and diagnosis of the ion beam by mass spectrometry. The system has been designed and simulated, and individual subsystems have been built and characterized experimentally. An injection trap for cooling and bunching of the ion beam has been developed, and cooling times of less than one millisecond have been achieved. The performance of the MR-TOF-MS was characterized using the isobaric doublet of carbon monoxide and nitrogen molecular ions. A mass resolving power of 10(5) (FWHM) has been obtained even with an uncooled ion population. The separator capabilities of the MR-TOF-MS have been demonstrated by removing either carbon monoxide or nitrogen ions from the beam in a Bradbury-Nielsen Gate after a flight time of 320 mu s. The separation power achieved is thus at least 7000 (FWHM) and increases for longer time-of-flight. An energy buncher stage has been designed that compresses the energy spread of the beam after the separation and facilitates efficient injection of the selected ions into in accumulation trap prior to transfer of the ions to experiments downstream of the MR-TOF-MS. (c) 2008 Elsevier B.V. All rights reserved.



Citation Styles

Harvard Citation stylePlass, W., Dickel, T., Czok, U., Geissel, H., Petrick, M., Reinheimer, K., et al. (2008) Isobar separation by time-of-flight mass spectrometry for low-energy radioactive ion beam facilities, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 266(19-20), pp. 4560-4564. https://doi.org/10.1016/j.nimb.2008.05.079

APA Citation stylePlass, W., Dickel, T., Czok, U., Geissel, H., Petrick, M., Reinheimer, K., Scheidenberger, C., & Yavor, M. (2008). Isobar separation by time-of-flight mass spectrometry for low-energy radioactive ion beam facilities. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 266(19-20), 4560-4564. https://doi.org/10.1016/j.nimb.2008.05.079



Keywords


Exotic nucleiIsobar separatorMASS MEASUREMENTSMultiple-reflection time-of-flight mass spectrometerRF Ion trap

Last updated on 2025-02-04 at 03:26