Konferenzpaper

The new readout electronics for the BaF2-calorimeter TAPS


AutorenlisteDrexler, P; Thöring, U; Bonn, W; van der Duin, HAP; Holzmann, R; van der Kruk, G; Krusche, B; Löhner, H; Metag, V; Nijboer, TW; Novotny, R; Potapov, A; Salz, C; Schadmand, S; Steinacher, M; Thiel, M; Vorenholt, H

Jahr der Veröffentlichung2003

Seiten969-973

ZeitschriftIEEE Transactions on Nuclear Science

Bandnummer50

Heftnummer4

ISSN0018-9499

DOI Linkhttps://doi.org/10.1109/TNS.2003.815166

KonferenzNuclear Science Symposium (NSS)/Symposium on Nuclear Power Systems (SNPS)

VerlagInstitute of Electrical and Electronics Engineers


Abstract
A highly compact and fast VME based readout board for BaF2 scintillation detectors has been designed, developed, and finally tested in an in-beam experiment. Adapted to the excellent properties of BaF2, the unit allows to digitize time, energy, and pulse-shape information of four detector channels in parallel. The board is piggy-back plugged onto a motherboard containing a high-speed 12-bit ADC and the VME interface, commercially available in the customized version CAEN V874 A. Both combine to one single VME slot. A first measurement of the photon response of a TAPS subarray with energy tagged photons up to 2.6 GeV documents the full functionality and excellent performance.



Zitierstile

Harvard-ZitierstilDrexler, P., Thöring, U., Bonn, W., van der Duin, H., Holzmann, R., van der Kruk, G., et al. (2003) The new readout electronics for the BaF2-calorimeter TAPS, IEEE Transactions on Nuclear Science, 50(4), pp. 969-973. https://doi.org/10.1109/TNS.2003.815166

APA-ZitierstilDrexler, P., Thöring, U., Bonn, W., van der Duin, H., Holzmann, R., van der Kruk, G., Krusche, B., Löhner, H., Metag, V., Nijboer, T., Novotny, R., Potapov, A., Salz, C., Schadmand, S., Steinacher, M., Thiel, M., & Vorenholt, H. (2003). The new readout electronics for the BaF2-calorimeter TAPS. IEEE Transactions on Nuclear Science. 50(4), 969-973. https://doi.org/10.1109/TNS.2003.815166



Schlagwörter


analog circuitsanalog-to-digital conversion (ADC)BaF2DETECTORGamma-ray detectorsPHOTON SPECTROMETER TAPSscintillatorstiming circuitsVME BOARD


Nachhaltigkeitsbezüge


Zuletzt aktualisiert 2025-02-04 um 04:16