Konferenzpaper
Autorenliste: Sikler, G; Ackermann, D; Attallah, F; Beck, D; Dilling, J; Elisseev, SA; Geissel, H; Habs, D; Habs, D; Heinz, S; Herfurth, F; Hessberger, F; Hofmann, S; Kluge, HJ; Kozhuharov, C; Marx, G; Mukherjee, M; Neumayr, J; Plass, WR; Quint, W; Rahaman, S; Rodriguez, D; Scheidenberger, C; Tarisien, M; Thirolf, P; Varentsov, V; Weber, C; Zhou, Z
Jahr der Veröffentlichung: 2003
Seiten: 482-486
Zeitschrift: Nuclear Instruments and Methods in Physics Research. Section B: Beam Interactions with Materials and Atoms
Bandnummer: 204
ISSN: 0168-583X
DOI Link: https://doi.org/10.1016/S0168-583X(02)02116-X
Konferenz: 14th International Conference on Electromagnetic Isotope Separators and Techniques Related the their Applications
Verlag: Elsevier
Abstract:
The ion trap facility SHIPTRAP is installed behind the separator for heavy ion reaction products (SHIP) at GSI, which is well known for the discovery of new super-heavy elements produced in cold fusion reactions. SHIPTRAP consists out of a gas cell for stopping the recoil ions delivered by SHIP and two linear radio frequency quadrupole (RFQ) structures for cooling and accumulating the ions. In a first Penning trap the radionuclides of interest get further cooled and isobaric contaminants are removed. The second Penning trap is intended for high-precision mass measurements or identification of the stored ions before providing them to further downstream experiments. During a first on-line experiment in 2001, ions from SHIP were stopped in the gas cell and transferred into the RFQ structures. Accumulation and cooling could be demonstrated. (C) 2002 Elsevier Science B.V. All rights reserved.
Zitierstile
Harvard-Zitierstil: Sikler, G., Ackermann, D., Attallah, F., Beck, D., Dilling, J., Elisseev, S., et al. (2003) First on-line test of SHIPTRAP, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 204, pp. 482-486. https://doi.org/10.1016/S0168-583X(02)02116-X
APA-Zitierstil: Sikler, G., Ackermann, D., Attallah, F., Beck, D., Dilling, J., Elisseev, S., Geissel, H., Habs, D., Habs, D., Heinz, S., Herfurth, F., Hessberger, F., Hofmann, S., Kluge, H., Kozhuharov, C., Marx, G., Mukherjee, M., Neumayr, J., Plass, W., ...Zhou, Z. (2003). First on-line test of SHIPTRAP. Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 204, 482-486. https://doi.org/10.1016/S0168-583X(02)02116-X
Schlagwörter
buffer gas; ion cooling; MASS-RATIO; PENNING TRAP; Radioactive Ion Beams; RFQ; time of flight; TRAP