Abstract
The response of PbWO4 to high-energy protons has been investigated in two test experiments at the proton facilities Cosy and AGOR. The determined energy resolution below 360 MeV of sigma/E = 1.44%/E-gamma(1/2) + 1.97% is comparable to the known photon response. Measured spectra of inelastically scattered protons below 85 MeV are even compared to similar distributions obtained for BaF2- and CeF3-detectors. (C) 2002 Elsevier Science B.V. All rights reserved.



Citation Styles

Harvard Citation styleHoek, M., Döring, W., Hejny, V., Löhner, H., Metag, V., Novotny, R., et al. (2002) Charged particle response of PbWO4, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 486(1-2), Article PII S0168-9002(02)00690-3, pp. 136-140. https://doi.org/10.1016/S0168-9002(02)00690-3

APA Citation styleHoek, M., Döring, W., Hejny, V., Löhner, H., Metag, V., Novotny, R., & Wörtche, H. (2002). Charged particle response of PbWO4. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 486(1-2), Article PII S0168-9002(02)00690-3, 136-140. https://doi.org/10.1016/S0168-9002(02)00690-3



Keywords


BaF2CeF3ENERGY REGIMEinorganic scintillatorMONOCHROMATIC PHOTONSPBWO4PBWO4-SCINTILLATOR ARRAYproton detection

Last updated on 2025-01-04 at 22:52