Abstract
The response of PbWO4 to high-energy protons has been investigated in two test experiments at the proton beam facilities COSY and AGOR. The determined energy resolution below 360 MeV of sigma/E = 0.97%/E-gamma(1/2) + 3.33% is comparable to the previously deduced photon response. Energy spectra of inelastically scattered protons below, 85 MeV are compared to similar distributions obtained for BaF2- and CeF3- detectors, respectively. The comparison to the response of charged pions indicates a strong quenching effect of the scintillation light for hydrogen isotopes.



Citation Styles

Harvard Citation styleHoek, M., Döring, W., Hejny, V., Löhner, H., Metag, V., Novotny, R., et al. (2002) Charged particle detection with PbWO4, IEEE Transactions on Nuclear Science, 49(3), Article PII S0018-9499(02)06162-2, pp. 946-949. https://doi.org/10.1109/TNS.2002.1039595

APA Citation styleHoek, M., Döring, W., Hejny, V., Löhner, H., Metag, V., Novotny, R., & Wörtche, H. (2002). Charged particle detection with PbWO4. IEEE Transactions on Nuclear Science. 49(3), Article PII S0018-9499(02)06162-2, 946-949. https://doi.org/10.1109/TNS.2002.1039595