Journal article

Numerical analysis of 4 K pulse tube coolers .2. Performances and internal processes


Authors listWang, C

Publication year1997

Pages215-220

JournalCryogenics

Volume number37

Issue number4

ISSN0011-2275

DOI Linkhttps://doi.org/10.1016/S0011-2275(97)00014-3

PublisherElsevier


Abstract
The processes and performance of two configurations of 4 K pulse tube coolers and a G-M cooler are analyzed by numerical simulation. A configuration of the pulse tube cooler where the phase shifter is located at room temperature does not lead to an efficient phase shifting of the moving liquid helium at the cold end. Several features, such as a flat temperature region in the low temperature regenerator and increased mass flow rate at the cold end of this regenerator, are revealed. Effects of double-inlet operation and structure parameters of the 4 K regenerator are also analyzed. (C) 1997 Elsevier Science Ltd.



Citation Styles

Harvard Citation styleWang, C. (1997) Numerical analysis of 4 K pulse tube coolers .2. Performances and internal processes, Cryogenics, 37(4), pp. 215-220. https://doi.org/10.1016/S0011-2275(97)00014-3

APA Citation styleWang, C. (1997). Numerical analysis of 4 K pulse tube coolers .2. Performances and internal processes. Cryogenics. 37(4), 215-220. https://doi.org/10.1016/S0011-2275(97)00014-3



Keywords


4 K pulse tube coolerinternal processes

Last updated on 2025-02-04 at 07:53