Abstract:
The production rates of neighboring short lived nuclides can vary over many orders of magnitude. In order to introduce a species of low production rate into a radioactive ion beam facility it is necessary to use an isotope separator whose mass cross contamination is extremely small. Such systems are discussed here featuring two magnetic sector-field stages at different electrostatic potentials as well as bunching capabilities. Such bunching allows to match the ion beam to an RF-accelerator and at the same time to purify the beam by a velocity separation.
Citation Styles
Harvard Citation style: WOLLNIK, H. (1995) ONLINE ISOTOPE SEPARATORS FOR RADIOACTIVE ION-BEAM FACILITIES, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 363(1-2), pp. 393-396. https://doi.org/10.1016/0168-9002(95)00163-8
APA Citation style: WOLLNIK, H. (1995). ONLINE ISOTOPE SEPARATORS FOR RADIOACTIVE ION-BEAM FACILITIES. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 363(1-2), 393-396. https://doi.org/10.1016/0168-9002(95)00163-8
Keywords
MASS SEPARATOR