RESPONSE OF TAPS TO MONOCHROMATIC PHOTONS WITH ENERGIES BETWEEN 45 AND 790 MEV


AutorenlisteGABLER, AR; DORING, W; FUCHS, M; KRUSCHE, B; METAG, V; NOVOTNY, R; ROBIGLANDAU, M; STROHER, H; TRIES, V; MOLENAAR, C; LOHNER, H; VANPOL, JHG; RASCHKE, A; SUMBERA, M; VENEMA, LB; WILSCHUT, HW; AVERBECK, R; NIEBUR, W; SCHUBERT, A; SIMON, RS; BECK, R; PEISE, J; MILLER, GJ; OWENS, RO; ANTON, G

Jahr der Veröffentlichung1994

Seiten168-176

ZeitschriftNuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

Bandnummer346

Heftnummer1-2

ISSN0168-9002

eISSN1872-9576

DOI Linkhttps://doi.org/10.1016/0168-9002(94)90701-3

VerlagElsevier


Abstract
The Two Arm Photon Spectrometer TAPS - comprising 384 plastic-BaF2 scintillator telescopes - was tested with monochromatic photons in the energy range between 45 and 790 MeV. The energy resolution for a collimated photon beam hitting the central detector module was determined to sigma/E = 0.59% X E(gamma)-1/2 + 1.9% (E, given in GeV). For the the fast scintillation component alone sigma/E = 0.79% X E(gamma)-1/2 + 1.8% has been measured. The position resolution of the point of impact amounts to DELTAx = 2 cm (FWHM) at the highest energies which corresponds to 30% of the diameter of an individual module. Monte Carlo simulations using the code GEANT3 are in good agreement with the experimental results.



Zitierstile

Harvard-ZitierstilGABLER, A., DORING, W., FUCHS, M., KRUSCHE, B., METAG, V., NOVOTNY, R., et al. (1994) RESPONSE OF TAPS TO MONOCHROMATIC PHOTONS WITH ENERGIES BETWEEN 45 AND 790 MEV, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 346(1-2), pp. 168-176. https://doi.org/10.1016/0168-9002(94)90701-3

APA-ZitierstilGABLER, A., DORING, W., FUCHS, M., KRUSCHE, B., METAG, V., NOVOTNY, R., ROBIGLANDAU, M., STROHER, H., TRIES, V., MOLENAAR, C., LOHNER, H., VANPOL, J., RASCHKE, A., SUMBERA, M., VENEMA, L., WILSCHUT, H., AVERBECK, R., NIEBUR, W., SCHUBERT, A., ...ANTON, G. (1994). RESPONSE OF TAPS TO MONOCHROMATIC PHOTONS WITH ENERGIES BETWEEN 45 AND 790 MEV. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 346(1-2), 168-176. https://doi.org/10.1016/0168-9002(94)90701-3



Schlagwörter


CALORIMETERMICROTRONSPECTROMETER