Conference paper

INFLUENCE OF REGENERATOR MATRIX AND WORKING FLUID ON OPTIMIZATION OF DESIGN PARAMETERS OF STIRLING CRYOCOOLERS


Authors listATREY, MD; BAPAT, SL; NARAYANKHEDKAR, KG

Publication year1994

Pages211-214

JournalCryogenics

Volume number34

ISSN0011-2275

DOI Linkhttps://doi.org/10.1016/S0011-2275(05)80045-1

Conference15th International Cryogenic Engineering Conference (ICEC 15)

PublisherElsevier


Abstract
The performance of Stirling cryocooler is governed by principal design parameters. The optimum combination of these design parameters gives maximum refrigeration effect and minimum desired efforts. The performance of the cryocooler depends significantly on the regenerator functioning and the working fluids. The mesh size of the regenerator affects dead space, pressure drop, regenerator effectiveness, etc. The working fluids differ in their thermal properties and therefore affect the performance significantly The present paper aims to study the influence of regenerator matrix and working fluids on these design parameters. The matrix material considered is Phosphor Bronze while the working fluids considered are Helium and Hydrogen.



Citation Styles

Harvard Citation styleATREY, M., BAPAT, S. and NARAYANKHEDKAR, K. (1994) INFLUENCE OF REGENERATOR MATRIX AND WORKING FLUID ON OPTIMIZATION OF DESIGN PARAMETERS OF STIRLING CRYOCOOLERS, Cryogenics, 34, pp. 211-214. https://doi.org/10.1016/S0011-2275(05)80045-1

APA Citation styleATREY, M., BAPAT, S., & NARAYANKHEDKAR, K. (1994). INFLUENCE OF REGENERATOR MATRIX AND WORKING FLUID ON OPTIMIZATION OF DESIGN PARAMETERS OF STIRLING CRYOCOOLERS. Cryogenics. 34, 211-214. https://doi.org/10.1016/S0011-2275(05)80045-1


Last updated on 2025-01-04 at 22:53