Abstract:
We present an apparatus that allows independent stimulation of rods and short (S)-, middle (M)-, and long (L)-wavelength-sensitive cones. Previously presented devices allow rod and cone stimulation independently, but only for a spatially invariant stimulus design (Pokorny, Smithson, & Quinlan, 2004; Sun, Pokorny, & Smith, 2001b). We overcame this limitation by using two spectrally filtered projectors with overlapping projections. This approach allows independent rod and cone stimulation in a dynamic two-dimensional scene with appropriate resolution in the spatial, temporal, and receptor domains. Modulation depths were +/- 15% for M-cones and L-cones, +/- 20% for rods, and +/- 50% for Scones, all with respect to an equal-energy mesopic background at 3.4 cd/m(2). Validation was provided by radiometric measures and behavioral data from two trichromats, one protanope, one deuteranope, and one night-blind observer.
Zitierstile
Harvard-Zitierstil: Bayer, F., Paulun, V., Weiss, D. and Gegenfurtner, K. (2015) A tetrachromatic display for the spatiotemporal control of rod and cone stimulation, Journal of Vision, 15(11), Article 15. https://doi.org/10.1167/15.11.15
APA-Zitierstil: Bayer, F., Paulun, V., Weiss, D., & Gegenfurtner, K. (2015). A tetrachromatic display for the spatiotemporal control of rod and cone stimulation. Journal of Vision. 15(11), Article 15. https://doi.org/10.1167/15.11.15