Journalartikel

Accuracy of Digital Impression Taking with Intraoral Scanners and Fabrication of CAD/CAM Posts and Cores in a Fully Digital Workflow


AutorenlisteLeven, Robert; Schmidt, Alexander; Binder, Roland; Kampschulte, Marian; Vogler, Jonas; Woestmann, Bernd; Schlenz, Maximiliane Amelie

Jahr der Veröffentlichung2022

ZeitschriftMaterials

Bandnummer15

Heftnummer12

eISSN1996-1944

Open Access StatusGold

DOI Linkhttps://doi.org/10.3390/ma15124199

VerlagMDPI


Abstract
Current intraoral scanners (IOS) enable direct impression taking for computer-aided de-sign/computer-aided manufacturing (CAD/CAM) posts and cores (P+C) with subsequent milling out of monolithic materials. The aim of this in vitro study was to systematically investigate the accuracy of CAD/CAM-P+C in a fully digital workflow, considering different IOS impression methods (Primescan (PRI), Trios4 without (TRI) and with scanpost (TRI+SP)) (Part A), and CAD/CAM milling of zirconium dioxid (ZIR) and resin composite (COM)-P+C (Part B). Five human models were developed in this study. Micro-CT imaging was used as a reference (REF). For Part A, the models were scanned 12 times for each impression method. Then, IOS datasets (n = 180) were superimposed with REF, and scan accuracy was determined using 3D software (GOMInspect). For Part B, one CAD/CAM-P+C (n = 30) was milled for each model, impression method, and material. The triple-scan method was applied using an industrial scanner (ATOS) to determine the accuracy of the fit. Statistical analysis was performed using analysis of variance (ANOVA, p < 0.05). Part A showed for PRI significantly lower accuracy than TRI and TRI+SP (p < 0.05). The data of Part B revealed significantly higher accuracy for ZIR than for COM (p < 0.05). Within the limitations of this study, CAD/CAM-P+C of the ZIR can be recommended for fabrication in a fully digital workflow regarding the accuracy of fit.



Zitierstile

Harvard-ZitierstilLeven, R., Schmidt, A., Binder, R., Kampschulte, M., Vogler, J., Woestmann, B., et al. (2022) Accuracy of Digital Impression Taking with Intraoral Scanners and Fabrication of CAD/CAM Posts and Cores in a Fully Digital Workflow, Materials, 15(12), Article 4199. https://doi.org/10.3390/ma15124199

APA-ZitierstilLeven, R., Schmidt, A., Binder, R., Kampschulte, M., Vogler, J., Woestmann, B., & Schlenz, M. (2022). Accuracy of Digital Impression Taking with Intraoral Scanners and Fabrication of CAD/CAM Posts and Cores in a Fully Digital Workflow. Materials. 15(12), Article 4199. https://doi.org/10.3390/ma15124199



Schlagwörter


CAD-CAMCERAMIC POSTCERAMICScomputer-aided manufacturingDENTISTRYDigital dentistrydigital workflowFIBER POSTFRACTURE-RESISTANCEINTERNAL FITIntraoral Scannermonolithic materialsMONOLITHIC ZIRCONIApost and core techniquePROSTHODONTICSRETENTION


Nachhaltigkeitsbezüge


Zuletzt aktualisiert 2025-10-06 um 11:41