Accuracy of Digital Impression Taking with Intraoral Scanners and Fabrication of CAD/CAM Posts and Cores in a Fully Digital Workflow


Authors listLeven, Robert; Schmidt, Alexander; Binder, Roland; Kampschulte, Marian; Vogler, Jonas; Woestmann, Bernd; Schlenz, Maximiliane Amelie

Publication year2022

JournalMaterials

Volume number15

Issue number12

eISSN1996-1944

Open access statusGold

DOI Linkhttps://doi.org/10.3390/ma15124199

PublisherMDPI


Abstract
Current intraoral scanners (IOS) enable direct impression taking for computer-aided de-sign/computer-aided manufacturing (CAD/CAM) posts and cores (P+C) with subsequent milling out of monolithic materials. The aim of this in vitro study was to systematically investigate the accuracy of CAD/CAM-P+C in a fully digital workflow, considering different IOS impression methods (Primescan (PRI), Trios4 without (TRI) and with scanpost (TRI+SP)) (Part A), and CAD/CAM milling of zirconium dioxid (ZIR) and resin composite (COM)-P+C (Part B). Five human models were developed in this study. Micro-CT imaging was used as a reference (REF). For Part A, the models were scanned 12 times for each impression method. Then, IOS datasets (n = 180) were superimposed with REF, and scan accuracy was determined using 3D software (GOMInspect). For Part B, one CAD/CAM-P+C (n = 30) was milled for each model, impression method, and material. The triple-scan method was applied using an industrial scanner (ATOS) to determine the accuracy of the fit. Statistical analysis was performed using analysis of variance (ANOVA, p < 0.05). Part A showed for PRI significantly lower accuracy than TRI and TRI+SP (p < 0.05). The data of Part B revealed significantly higher accuracy for ZIR than for COM (p < 0.05). Within the limitations of this study, CAD/CAM-P+C of the ZIR can be recommended for fabrication in a fully digital workflow regarding the accuracy of fit.



Citation Styles

Harvard Citation styleLeven, R., Schmidt, A., Binder, R., Kampschulte, M., Vogler, J., Woestmann, B., et al. (2022) Accuracy of Digital Impression Taking with Intraoral Scanners and Fabrication of CAD/CAM Posts and Cores in a Fully Digital Workflow, Materials, 15(12), Article 4199. https://doi.org/10.3390/ma15124199

APA Citation styleLeven, R., Schmidt, A., Binder, R., Kampschulte, M., Vogler, J., Woestmann, B., & Schlenz, M. (2022). Accuracy of Digital Impression Taking with Intraoral Scanners and Fabrication of CAD/CAM Posts and Cores in a Fully Digital Workflow. Materials. 15(12), Article 4199. https://doi.org/10.3390/ma15124199



Keywords


CAD-CAMCERAMIC POSTCERAMICScomputer-aided manufacturingDENTISTRYDigital dentistrydigital workflowFIBER POSTFRACTURE-RESISTANCEINTERNAL FITIntraoral Scannermonolithic materialsMONOLITHIC ZIRCONIApost and core techniquePROSTHODONTICSRETENTION