Abstract
An experimental investigation on two-component multi-phase helium and nitrogen mixtures in a single-stage pulse tube refrigerator was carried out. The experimental results show that both coefficient of performance (COP) and cooling power can be improved to some extent at above 70 K when the nitrogen fraction in the mixture is less than 25%. An approximate stable temperature platform at the triple point 63.15 K of nitrogen, which is independent of nitrogen's fraction, is obtained when the cooling power is below 7 W. (C) 2000 Elsevier Science Ltd. All rights reserved.



Citation Styles

Harvard Citation styleGan, Z., Chen, G., Thummes, G. and Heiden, C. (2000) Experimental study on pulse tube refrigeration with helium and nitrogen mixtures, Cryogenics, 40(4-5), pp. 333-339. https://doi.org/10.1016/S0011-2275(00)00047-3

APA Citation styleGan, Z., Chen, G., Thummes, G., & Heiden, C. (2000). Experimental study on pulse tube refrigeration with helium and nitrogen mixtures. Cryogenics. 40(4-5), 333-339. https://doi.org/10.1016/S0011-2275(00)00047-3



Keywords


gas mixturespulse tubetwo-phase flow