Journalartikel

Experimental study on pulse tube refrigeration with helium and nitrogen mixtures


AutorenlisteGan, ZH; Chen, GB; Thummes, G; Heiden, C

Jahr der Veröffentlichung2000

Seiten333-339

ZeitschriftCryogenics

Bandnummer40

Heftnummer4-5

ISSN0011-2275

eISSN1879-2235

DOI Linkhttps://doi.org/10.1016/S0011-2275(00)00047-3

VerlagElsevier


Abstract
An experimental investigation on two-component multi-phase helium and nitrogen mixtures in a single-stage pulse tube refrigerator was carried out. The experimental results show that both coefficient of performance (COP) and cooling power can be improved to some extent at above 70 K when the nitrogen fraction in the mixture is less than 25%. An approximate stable temperature platform at the triple point 63.15 K of nitrogen, which is independent of nitrogen's fraction, is obtained when the cooling power is below 7 W. (C) 2000 Elsevier Science Ltd. All rights reserved.



Zitierstile

Harvard-ZitierstilGan, Z., Chen, G., Thummes, G. and Heiden, C. (2000) Experimental study on pulse tube refrigeration with helium and nitrogen mixtures, Cryogenics, 40(4-5), pp. 333-339. https://doi.org/10.1016/S0011-2275(00)00047-3

APA-ZitierstilGan, Z., Chen, G., Thummes, G., & Heiden, C. (2000). Experimental study on pulse tube refrigeration with helium and nitrogen mixtures. Cryogenics. 40(4-5), 333-339. https://doi.org/10.1016/S0011-2275(00)00047-3



Schlagwörter


gas mixturespulse tubetwo-phase flow


Nachhaltigkeitsbezüge