Approaching the He-4 lambda line with a liquid nitrogen precooled two-stage pulse tube refrigerator


AutorenlisteThummes, G; Bender, S; Heiden, C

Jahr der Veröffentlichung1996

Seiten709-711

ZeitschriftCryogenics

Bandnummer36

Heftnummer9

ISSN0011-2275

DOI Linkhttps://doi.org/10.1016/0011-2275(96)00060-4

VerlagElsevier


Abstract
We report on the design and test of a three-stage refrigerator, consisting of a liquid nitrogen bath with heat exchangers and two subsequent pulse tube stages. The liquid nitrogen bath serves for precooling the oscillating He-4-gas flow. The PTR stages are operated in orifice and double-inlet mode with the orifice valves, reservoirs and second-inlet valves located at ambient temperature. Er3Ni shot is used for the regenerator matrix in the coldest stage. A minimum temperature of 2.13(1)K has been achieved, which, at the average operating pressure of 19.5 bar, is only 0.19 K above the lambda-line for the superfluid phase transition of He-4. (C) 1996 Elsevier Science Limited