Konferenzpaper

Influences on Langmuir Probe Measurements by an ECR Thruster with Magnetic Nozzle


AutorenlisteSchäfer, Clara; Zorn, Jana; Holste, Kristof; Klar, Peter J.

Erschienen inNew Results in Numerical and Experimental Fluid Mechanics XIV

HerausgeberlisteDillmann, Andreas; Heller, Gerd; Krämer, Ewald; Wagner, Claus; Weiss, Julien

Jahr der Veröffentlichung2024

Seiten153-162

ISBN978-3-031-40481-8

eISBN978-3-031-40482-5

DOI Linkhttps://doi.org/10.1007/978-3-031-40482-5_15

KonferenzSTAB/DGLR Symposium

SerientitelNotes on Numerical Fluid Mechanics and Multidisciplinary Design

Serienzählung154


Abstract

Ensuring reliability in the measurement and interpretation of plasma diagnostics is essential for characterizing thruster concepts in the growing field of electric propulsion. Langmuir probes are often used to determine the properties of low temperature plasmas. However, not much research is found on Langmuir probe measurements on electron cyclotron resonance thrusters with magnetic nozzle, especially no detailed studies on variable probe orientations with respect to magnetic field lines. The question arises which differences can be shown in the electron energy distribution regarding the probes orientation and in what way it is possible to interpret probe alignment consequences on determined plasma characteristics. We perform our study as follows: We measure in two orientations, parallel and orthogonal to magnetic field lines, at different operating states of the thruster (variable power and volume flow settings). The Langmuir probe data shows clearly a dependency on the probes orientation. We use the measured ion energy distribution of the retarding potential analyzer as a comparison tool to the determined electron energy distribution of the single Langmuir probe measurements. Due to the determined anisotropic non-Maxwellian distribution mainly visible in parallel orientation we conclude a parallel orientation of Langmuir probes with respect to magnetic field lines is preferable for ECRT with MN.




Autoren/Herausgeber




Zitierstile

Harvard-ZitierstilSchäfer, C., Zorn, J., Holste, K. and Klar, P. (2024) Influences on Langmuir Probe Measurements by an ECR Thruster with Magnetic Nozzle, in Dillmann, A., Heller, G., Krämer, E., Wagner, C. and Weiss, J. (eds.) New Results in Numerical and Experimental Fluid Mechanics XIV. Cham: Springer. pp. 153-162. https://doi.org/10.1007/978-3-031-40482-5_15

APA-ZitierstilSchäfer, C., Zorn, J., Holste, K., & Klar, P. (2024). Influences on Langmuir Probe Measurements by an ECR Thruster with Magnetic Nozzle. In Dillmann, A., Heller, G., Krämer, E., Wagner, C., & Weiss, J. (Eds.), New Results in Numerical and Experimental Fluid Mechanics XIV. (pp. 153-162). Springer. https://doi.org/10.1007/978-3-031-40482-5_15


Zuletzt aktualisiert 2025-17-07 um 14:40